Part no.: 09 0572 02 08
M16 Female cable connector, Contacts: 8 (08-a), 6.0-8.0 mm, unshielded, solder, IP40
M16 IP40, series 680, Miniature Connectors
General features
MorelessPart no. | 09 0572 02 08 |
Connector design | Female cable connector |
Type standard | DIN EN 61076-2-106 |
Version | Connector socket straight |
Connector locking system | screw |
Termination | solder |
Degree of protection | IP40 |
Cross-sectional area | 0.75 mm² / AWG 18 |
Cable outlet | 6.0-8.0 mm |
Temperature range from/to | -40 °C / 85 °C |
Mechanical operation | > 500 Mating cycles |
Weight (g) | 18.41 |
Customs tariff number | 85369010 |
Country of Origin | DE |
Electrical parameters
MorelessRated voltage | 60 V |
Rated impulse voltage | 500 V |
Rated current | 5.0 A |
Insulation resistance | ≥ 1010 Ω |
Pollution degree | 1 |
Overvoltage category | I |
Insulating material group | III |
EMC compliance | unshielded |
Material
MorelessHousing material | PA |
Contact body material | PBT (UL94 V-0) |
Contact material | CuSn (bronze) |
Contact plating | Ag (silver) |
REACH SVHC |
CAS 7439-92-1 (Lead) |
SCIP number | 5d6ebb70-5603-4dfb-8271-361302e66dda |
Classifications
MorelesseCl@ss 11.1 | 27-44-01-09 |
ETIM 9.0 | EC003569 |
Declarations of conformity
MorelessLow Voltage Directive | 2014/35/EU (EN 60204-1:2018;EN 60529:1991) |
Security notices
- The connector must not be plugged or unplugged under load. Non-observance and improper use can result in personal injury.
- The connectors have been developed for applications in plant engineering, control and electrical equipment construction. The user is responsible for checking whether the connectors can also be used in other areas of application.
- To protect against unintentional opening of the connector, the thread between the housing and the connector head must be secured with a suitable cyanoacrylate adhesive when used in circuits with voltages dangerous to the touch. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors which are used in circuits with voltages dangerous to the touch may only be installed and used by, or under the supervision of, persons with electrical engineering training, taking into account the applicable regulations and standards.
- The user must take suitable safety precautions to ensure that the connector cannot be accidentally disconnected.
- The plug connector is not suitable for mains voltages Please observe the pollution degree and the overvoltage category. For further information, please refer to the download center "Technical Information".
- To lock the cable connector with the device connector, the threaded ring is tightened "hand-tight" (approx. 60 cNm).
Downloads