Menu
Back
  1. Products
  2. Power connectors
  3. RD24 Power
  4. RD24 Female cable connector, Contacts: 6+PE, 10.0-12.0 mm, unshielded, crimping (Crimp contacts must be ordered separately), IP67, UL, ESTI+, VDE, PG 13.5
Part no.: 99 4202 14 07

RD24 Female cable connector, Contacts: 6+PE, 10.0-12.0 mm, unshielded, crimping (Crimp contacts must be ordered separately), IP67, UL, ESTI+, VDE, PG 13.5

RD24, series 693, Power Connectors
Available numbers of contacts
Compare product
Downloads
General features
Moreless
Part no. 99 4202 14 07
Connector design Female cable connector
Version Connector socket straight
Connector locking system screw
Termination crimping (Crimp contacts must be ordered separately)
Degree of protection IP67
Cross-sectional area click here for more info
Cable outlet 10.0-12.0 mm
Temperature range from/to -40 °C / 100 °C
Mechanical operation > 500 Mating cycles
Weight (g) 37.11
Customs tariff number 85369010
Country of Origin DE
Rated voltage 250 V
Rated impulse voltage 4000 V
Rated current 10 A (8 A UL)
Insulation resistance ≥ 1010 Ω
Pollution degree 3
Overvoltage category III
Insulating material group III
EMC compliance unshielded
Contact body material PBT (UL94 V-0)
Contact material depending on crimp contact (accessory)
Contact plating Ag (silver)
REACH SVHC None (No pollutants)
SCIP number SCIP-number not available
Approvals UL, ESTI+, VDE
eCl@ss 11.1 27-44-01-02
ETIM 9.0 EC002635
Low Voltage Directive 2014/35/EU (EN 60204-1:2018;EN 60529:1991)
Security notices
  1. The connector must not be plugged or unplugged under load. Non-observance and improper use can result in personal injury.
  2. The connectors have been developed for applications in plant engineering, control and electrical equipment construction. The user is responsible for checking whether the connectors can also be used in other areas of application.
  3. To protect against unintentional opening of the connector, the thread between the housing and the connector head must be secured with a suitable cyanoacrylate adhesive when used in circuits with voltages dangerous to the touch. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
  4. Connectors which are used in circuits with voltages dangerous to the touch may only be installed and used by, or under the supervision of, persons with electrical engineering training, taking into account the applicable regulations and standards.
  5. The user must take suitable safety precautions to ensure that the connector cannot be accidentally disconnected.
  6. The plug connector is not suitable for mains voltages Please observe the pollution degree and the overvoltage category. For further information, please refer to the download center "Technical Information".
Downloads
Data sheet
Data sheet 99 4202 14 07
PDF
Data sheet, Data sheet 99 4202 14 07
Certificates
UL certificate
PDF, 289.18 KB
Certificates, UL certificate
Certificates
VDE certificate
PDF, 671.99 KB
Certificates, VDE certificate
Certificates
Splus certificate
PDF, 2.82 MB
REACH
99 4202 14 07
PDF
RoHS
99 4202 14 07
PDF
China RoHS
99 4202 14 07
PDF
Declaration of conformity, Low Voltage Directive
Declaration of conformity
Low Voltage Directive
PDF
UKCA declaration of conformity, Electrical Equipment
UKCA declaration of conformity
Electrical Equipment
PDF
CAD files
Select required format
RD24 Power
99 4202 14 07